N500 INSTRUCTION MANUAL Explanation of Function 2.3 Code List Monitor M Monitor M Monitor M Monitor Mode ode ode ode (D (D (D (D-Group) Group) Group) Group) Basic Function Mode Basic Function Mode Basic Function Mode Basic Function Mode (F (F (F (F-Group) Group) Group) Group) 2-7 Setting Display Read/ Function name Monitor range Initial data on Page code Copy running Monitor function D01 Output frequency monitor Out F Mon _ 0.00~400.00Hz 0.00Hz X X 2-15 D02 Output current monitor Out I Mon _ 0.0~ 6553.5A 0.0A X X 2-15 D03 Output voltage monitor Out V Mon _ 0.0~ 6553.5V 0.0V X X 2-15 D04 DC rink voltage DC V Mon _ 0.0~ 6553.5V 0.0V X X 2-15 D05 Direction/ Motor rotational speed Speed Mon 0.0~ 6553.5RPM 0.0RPM X X 2-15 D06 PID feedback monitor PID FB Mon 0.0~ 250.0% 0.0% X X 2-15 D07 Intelligent input terminal monitor I 87654421 _ 00000000~11111111 00000000 X X 2-15 D08 Intelligent output terminal monitor O 87654421 _ 00000000~11111111 00100000 X X 2-16 D09 Power dissipation monitor IPower Mon 0.0~ 6553.5kW 0.0KW X X 2-16 D10 Accumulated time monitor on RUN Run Time 00000~ 65535H 00~ 59M 0H 0M X X 2-16 D11 Power ON time monitor P On Time _ 00000~ 65535H 00~ 59M 0H 0M X X 2-16 Setting Function Initial Read/ Function name Data range on Page code data Copy running Main setting F01 Output frequency setting Out F Set _ B10(Min F Set) ~ A04(Max F Set) _ _ _ _ 000.00Hz O O 2-17 F02 1st acceleration time Acc Time 0.01 ~ 3600Sec 0060.0Sec O O 2-17 F03 1st deceleration time Dec Time 0.01 ~ 3600Sec 0060.0Sec O O 2-17 F04 Operation direction selection No Run Dir 0~2 (NON,FWD,REV) 0 X O 2-17