omron — Руководство по эксплуатации PMAC - системы контроля движения (EN)

PMAC Quick Reference Guide Appendix B – PMAC I-Variables Summary 79 Coordinate System I- Variables Range Default Units Ix87 C.S. x Default Acceleration Time 0 .. 8,388,607 0 (so Ix88 controls) Msec Ix88 C.S. x Default S-Curve Time 0 .. 8,388,607 50 Msec Ix89 C.S. x Default Feedrate Positive floating point 1000 (User position units)/(feedrate time units) Ix90 C.S. x Feedrate Time Units Positive floating point 1000.0 Msec Ix91 C.S. x Default Working Program Number 0 .. 32,767 0 Motion Program Numbers Ix92 C.S. x Move Blend Disable 0 .. 1 0 None Ix93 C.S. x Time Base Address PMAC "X" addresses See Ix93 table Legal PMAC addresses Ix94 C.S. x Time Base Slew Rate 0 ..

8,388,607 1644 2-23msec/ servo cycle Ix95 C.S. x FeedHold Decel Rate 0 .. 8,388,607 1644 2-23msec/servo cycle Ix96 C.S. x Circle Error Limit Positive floating point 0 (function disabled) User length units Ix98 Coordinate System x Maximum Feedrate Non-negative floating-point 0 None Encoder/Flag Setup I- Variables Range Default Units I900, I905,.. Encoder 0 Decode Control 0 .. 15 7 None I901, I906,.. Encoder 0 Delay Filter Disable 0 .. 1 0 None I902, I907,.. Encoder 0 Capture Control 0 .. 15 1 None I903, I908,.. Encoder 0 Flag Select 0 .. 3 0 None MACRO Support I-Variables Range Default Units I1000 MACRO Node Auxiliary Register Enable 0 .. $FFFF (0 ..

65,535) $0 None I1001 MACRO Ring Check Period 0 .. 255 0 Servo cycles I1003 MACRO Type 1 Master/Slave Comm. Timeout 0 .. 255 0 Servo cycles I1004 MACRO Ring Error Shutdown Count 0 MACRO ring errors I1005 MACRO Ring Sync Packet Shutdown Count 0 .. 65,535 MACRO sync packets