Downloaded from https://www.everyspec.com MIL-STD-1311D ELECTRODE VOLTAGE 1. Purpose. To measure the particular electrode voltage at the point in the circuit and in the manner specified. 2. Equipment. Instruments of proper impedance shall be used to have negligible effect on the performance of the circuit or the indicated value. 3. Procedure. With the specified voltages and currents applied and the specified currents flowing to the electrode concerned, its voltages shall be within the specified limit(s). NOTE: When the electrode-voltage tests are performed on converter-type receiving tubes, no signal shall be applied to the signal grid. METHOD 1261 METHOD 1261 1261-1 19 April 1968