U.S. Department of Defense MIL-STD-810D — vdj6225.tmp (EN)

Downloaded from https://www.everyspec.com MIL-STD-810D I 19 JUIY 1983 Ideal Trapezoidal Pulse ‘1 TEST PEAK VALUE (Am) NOMINAL DURATION (TD) ms Fragility 10 to 50 2=) Packaged 30 Am Shock NOTE: The time history display shall include a time about 3TD long with a pulse located approximate y in the center. The peak acceleration magnitude of the trapezoidal pulse is Am and its duration is TD.

The measured acceleration pulse shall be contained between the brOken line boundaries and the measured velocity change (which may be obtained by integration.of the acceleration pulse) shall be within ten percent of the ideal pulse which approximately equals o.5 Am g (2TD-TR-TF)o ‘integration‘o ‘etermine velocity change shall extend from O .QTD before the Pulse tO O.lTD after the pulse. Rise (TR) and fall (TF) times shall be less than Or equal 0.1TD. ,, FIGURE 516.3-5. lse configuration and iti% 11 ante mlta. M3THOD 516.3 19 July 1983 516.3-10