U.S. Department of Defense MIL-STD-810D — vdj6225.tmp (EN)

Downloaded from https://www.everyspec.com MIL-STD-810D 19 July 1983 Step 15. With the test item not operating, adjust the chamber air temperature to controlled ambient conditions and maintain until temperature stabilization of”the test item has been achieved.. Step 16. Conduct a complete visual examination and an operational checkout in accordance with the approved test plan and document the results. Step 17. Compare these data with the pretest data. II-4 TO BE ~ J a. Previous tests to which the test item has been subjected. .b. Results of each performance check and visual examination (and photographs, if applicable) and comparison with the failure criteria: . (1) Pretest. (2) During teat.

(3) Post-test. chamber temperatures (and humidity if applicable) versus o c. Record of time coriditions. d. Record of the test item temperature-versus-timedata for the duration of the test. e. Initial failure analysia. . ~. METHOD 501,2 501.2-17 19 July 1983