2.2 Removal and reinstallation of the operation panel or the front covers Removal and reinstallation of the operation panel Loosen the two screws on the operation panel. (These Press the upper edge of the operation panel while pulling screws cannot be removed.) out the operation panel. 00770(30K) or lower) (a) Loosen Loosen Loosen (a) Loosen the screws on the lower front cover. (These screws cannot be removed.) (b) While holding the areas around the installation hooks on the sides of the lower front cover, pull out the cover using its upper side as a support. (c) With the lower front cover removed, the main circuit and the control circuit can be wired. 34 2.
INSTALLATION AND WIRING 2.2 Removal and reinstallation of the operation panel or the front covers onnector on the back wi panel is fit securely, tigh ont cover (FR- (b) th the PU connector of the inverter, and insert the oper ten the screws. (Tightening torque: 0.40 to 0.45 N·m) A820-01540(30K) or lower, FR-A8 (c)