Mitsubishi FR-A800 — 2.5.3 Recommended cables and wiring length

1 2 3 200 V class (220 V input power supply, with a power factor improving AC or DC reactor) 4 5 6 7 8 9 10 400 V class (440 V input power supply, without a power factor improving AC or DC reactor) 61 2. INSTALLATION AND WIRING 2.5 Main circuit terminals Applicable inverter model FR-A820-[] Terminal screw size*4 Tightening torque (N·m) Crimp terminal Cable gauge HIV cables, etc. (mm2)*1 AWG/MCM*2 PVC cables, etc.

(mm2)*3 R/L1, S/ L2, T/L3 U, V, W R/L1, S/L2, T/L3 U, V, W P/+, P1 Earthing (grounding) cable R/L1, S/L2, T/L3 U, V, W R/L1, S/L2, T/L3 U, V, W Earthing (grounding) cable 00770(15K) M6 4.4 38-6 22-6 38 22 38 14 2 4 50 25 25 00930(18.5K) M8 (M6) 7.8 38-8 38-8 38 38 38 22 2 2 50 50 25 01250(22K) M8 (M6) 7.8 60-8 60-8 60 60 60 22 1/0 1/0 50 50 25 01540(30K) M8 (M6) 7.8 80-8 80-8 80 80 80 22 3/0 3/0 70 70 35 01870(37K) M10 (M8) 26.5 100-10 100-10 100 100 100 38 4/0 4/0 95 95 50 02330(45K) M10 (M8) 26.5 100-10 100-10 100 100 100 38 4/0 4/0 95 95 50 Applicable inverter model FR-A820-[] Terminal screw size*4 Tightening torque (N·m) Crimp terminal Cable gauge HIV cables, etc.

(mm2)*1 AWG/MCM*2 PVC cables, etc.

(mm2)*3 R/L1, S/ L2, T/ L3 U, V, W R/L1, S/L2, T/L3 U, V, W P/+, P1 Earthing (grounding) cable R/L1, S/L2, T/L3 U, V, W R/L1, S/L2, T/L3 U, V, W Earthing (grounding) cable 00046(0.4K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00077(0.75K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00105(1.5K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00167(2.2K) M4 1.5 5.5-4 5.5-4 3.5 3.5 3.5 3.5 12 12 4 4 4 00250(3.7K) M4 1.5 5.5-4 5.5-4 5.5 5.5 5.5 5.5 10 10 6 6 6 00340(5.5K) M5 (M4) 2.5 8-5 8-5 8 8 14 5.5 8 8 10 10 10 00490(7.5K) M5 (M4) 2.5 14-5 14-5 14 14 14 8 6 6 16 16 16 00630(11K) M5 2.5 22-5 22-5 22 22 22 14 4 4 25 25 16 00770(15K) M6 4.4 22-6 22-6 22 22 38 14 4 4 25 25 25 00930(18.5K) M8 (M6) 7.8 38-8 38-8 38 38 38 22 2 2 50 50 25 01250(22K) M8 (M6) 7.8 60-8 60-8 60 60 60 22 1/0 1/0 50 50 25 01540(30K) M8 (M6) 7.8 80-8 80-8 80 80 80 22 3/0 3/0 70 70 35 01870(37K) M10 (M8) 26.5 100-10 100-10 100 100 100 38 4/0 4/0 95 95 50 02330(45K) M10 (M8) 26.5 100-10 100-10 100 100 100 38 4/0 4/0 95 95 50 03160(55K) M12 (M8) 46 150-12 150-12 125 125 125 38 250 250 120 120 — 03800(75K) M12 (M8) 46 150-12 150-12 150 150 150 38 2×4/0 2×4/0 2×95 2×95 — 04750(90K) M12 (M8) 46 100-12 100-12 2×100 2×100 2×100 60 2×4/0 2×4/0 2×95 2×95 — Applicable inverter model FR-A840-[] Terminal screw size*4 Tightening torque (N·m) Crimp terminal Cable gauge HIV cables, etc.

(mm2)*1 AWG/MCM*2 PVC cables, etc.

(mm2)*3 R/L1, S/ L2, T/ L3 U, V, W R/L1, S/L2, T/L3 U, V, W P/+, P1 Earthing (grounding) cable R/L1, S/L2, T/L3 U, V, W R/L1, S/L2, T/L3 U, V, W Earthing (grounding) cable 00023(0.4K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00038(0.75K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00052(1.5K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00083(2.2K) M4 1.5 2-4 2-4 2 2 2 2 14 14 2.5 2.5 2.5 00126(3.7K) M4 1.5 2-4 2-4 2 2 3.5 3.5 12 14 2.5 2.5 4 00170(5.5K) M4 1.5 5.5-4 5.5-4 3.5 3.5 3.5 3.5 12 12 4 4 4 00250(7.5K) M4 1.5 5.5-4 5.5-4 5.5 5.5 5.5 5.5 10 10 6 6 10 00310(11K) M5 2.5 8-5 5.5-5 8 5.5 8 5.5 8 10 10 6 10 00380(15K) M5 2.5 14-5 8-5 14 8 14 8 6 8 16 10 16 00470(18.5K) M6 4.4 14-6 14-6 14 14 22 14 6 6 16 16 16 00620(22K) M6 4.4 22-6 22-6 22 22 22 14 4 4 25 25 16 00770(30K) M6 4.4 22-6 22-6 22 22 22 14 4 4 25 25 16 00930(37K) M8 7.8 38-8 38-8 38 38 38 22 1 2 50 50 25 01160(45K) M8 7.8 60-8 60-8 60 60 60 22 1/0 1/0 50 50 25