EPSON — ML-16000-180/ ML-32000-180

Specifications Power ML-16000-180/ ML-32000-180 Factory facilities 17 Item Specifications Notes Voltage 400 V ± 10 %, 3-phase + Neutral + Earth Frequency 50 / 60 Hz ± 3 % Rated apparent power 20.7 kVA Power consumption Printing Approx. 5.5 kW Power consumption (with hot roller option) Printing Approx. 12 kW Rated current 30 A Leakage current 300 mA or less Factory facilities Connected/Wired Type: Terminal block connection Connecting part model: Power: CB510 (Manufacturer. by Cabur) Ground: TO210 (Manufacturer. by Cabur) Compatible crimped terminals (reference): Ferrule type WP160/22 Wiring specifications (recommended):

600 V withstand voltage (UL1063 equivalent) Wire size of 10 mm2 (AWG8) or larger Item Specifications Notes Compressed air Pressure: Min. 0.6 MPa (6 bar) Required air flow capacity: 250 L/min Connector: User: Tube Φ12 mm (O.D) Machine: Fitting Φ12 mm Required for raising/lowering the cleaning tank, ink pressure, etc. Air consumption is the amount of air in an hour. This is used to select compressors. The required air flow capacity is the flow rate which needs to be supplied from factory to the machine within a short period of time. This is used to select the main piping to the machine. Water Pressure: 0.4 Mpa (4 bar) - 0.6 MPa (6 bar) Flow rate: Max. 100 Liter/hr {6,102 in3/h} Connector:

User: Horse + Fitting (R3/4) Machine: Fitting (Rc3/4) Required for belt cleaning.