Residual Risks 25 No. Operation stage Work Qualification / training required for work Location on machine Residual risk *1 (Degree of harm) Content of harm Protective measure to be implemented by machine user Page to be refer- enced 3 Opera- tion Loading the Fabric (Loading the fabric on the pressure roller) Must understand the content of the User's Manual and have undergone operational training from a Seiko Epson Group service / support representative or a service representative authorized by Seiko Epson. Printer unit (Pressure roller section) WARNING The strong magnetic field could cause a malfunc- tion in heart pace- makers.
Workers using heart pacemakers should not come near the relevant locations. Page 33, Page 37 4 Mainte- nance Maintenanc e work such as cleaning the machine interior Printer unit (Scan spindle section) WARNING The strong magnetic field could cause a malfunc- tion in heart pace- makers. Workers using heart pacemakers should not come near the relevant locations. Page 30 5 Mainte- nance Application work of materials containing organic solvent (Removal or application of glue) Printer unit (Feeding belt section) CAUTION When removing or apply- ing glue, there is a risk of inhaling harmful vapors released by the glue or remover, or of it becoming adhered to your skin.
Be sure to use appropriate personal protective equipment, and to ventilate the work environment. Page 41