Omron Microscan Systems, Inc . | 700 SW 39th St. | Renton, WA 98057 | Tel: 425.226.5700 | Fax: 425.226.8250 Technical Note MS-890 Ethernet Connectivity Guide This document describes how to transition from the MS-890 with Ethernet Protocol Card to Ethernet functionality using a standard MS-890 and an Ethernet-enabled MS-Connect 210. MS-890 Ethernet Originally, the MS-890 Scanner could be used as an Ethernet device in conjunction with an Ethernet Protocol Card (98-000056-02) in the scanner’s wiring box. The Ethernet Protocol Card is no longer available, but a standard MS-890 can still be enabled for Ethernet connectivity with an MS-Connect 210 connectivity box.
MS-890 and MS-Connect 210 Ethernet Hardware 2 • Attach the 19-pin to 25-pin Reader Cable ( 3 ) to the MS-Connect 210 ( 2 ) via the 19-pin reader connector, shown in the illustration at left. • Tighten the 19-pin reader connector on the back of the MS-Connect 210 unit. • Attach Ethernet cable ( 6 ) to the silver module inside the wiring box, and attach the other end to the network. • If required by the application, attach a Trigger ( 5 ) to the MS-Connect 210 via the trigger connector, shown in the illustration at left. • Attach the Power Supply ( 4 ) to the MS-Connect 210 via the power Micro-Change connector, shown in the illustration at left. 6 1 4 5 CAUTION:
Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables. Note: See the MS-Connect 210 User Manual for detailed information about configuring the MS-Connect 210 display, wiring, and configuring output settings. 3 System Matrix Product Part Number Description (continued next page) Copyright ©2018 Omron Microscan Systems, Inc. P/N 83-220121 Rev A (1) MS-890 FIS-0890-0001G Industrial Automation Scanner (2) MS-Connect 210 FIS-0210-0003G FIS-0210-0004G Wiring Box, Ethernet, Display Wiring Box, Ethernet (3) Reader Cable 61-000123-01 MS-890 to MS-Connect 210 cable, Host RS-232/AUX. RS-232, 6 ft.
(4) Power Supply 97-100004-15 90-264 VAC, 24VDC, USA/Euro plug (5) Trigger (if required) 99-000004-01 Photo Sensor, Std. Diffuse, 120” range, 4-pin Plug (6) MS-Connect 210 Ethernet Cable User-supplied Ethernet Cable, RJ45 Connector
Configuring the MS-890 and MS-Connect 210 for Ethernet The following procedure describes how to configure a standard MS-890 and an Ethernet-enabled MS-Connect 210 for Ethernet communications. 1. Power-on the hardware configuration. 2. Launch ESP Software, select the MS-Connect 210 from the model menu, and configure MS-Connect 210-to-Host Ethernet gateway settings and MS-890-to-MS-Connect 210 serial port settings. 3. Click the Switch Model button in ESP and select the MS-890 from the model menu. 4. Select Connection Wizard from the Connect dropdown menu. Select Ethernet , and then set the IP Address and Primary TCP Port to match those of the MS-Connect 210. 5.
When a connection is established, use ESP to configure the MS-890 as required for your application. Refer to the MS-890 Industrial Automation Scanner User Manual and the MS-Connect 210 User Manual for detailed information about hardware, communications, and configuring network parameters. Copyright ©2018 Omron Microscan Systems, Inc. Click Search to locate your MS-Connect 210. The MS-Connect 210’s IP address and MAC address will appear in this field. Important: The unit’s MAC address is printed on the top of the Ethernet module inside the box.
Set Baud Rate, Parity, Stop Bits, and Data Bits to match the corresponding settings in the MS-890 Host Port (9600 Baud, Even Parity, 1 Stop Bit, 7 Data Bits. In the TCP/IP dialog, match the IP address and TCP port to the MS-Connect 210 and click Connect. When a connection is established, you can begin configuring the reader in ESP.