2 System Design z Addresses allocation table Memory allocation table 2-2 Demonstration System 2 The I/O relays of the PLC are allocated as follows.
LS1(0.05) MO1(100.00) MO2(100.01) LS2(0.06) SEN1(0.03) SEN2(0.04) NB-series Programmable Terminals Startup Guide Manual(V109) 2-7 Addresses Function Component Name Corresponding Screen W bit 0.01 _ Automatically close (disabled) Bit Button Fully Open W bit 0.02 _ Start the maintenance screen Bit Button Wait W bit 1.00 _ Open Bit Button/ Bit Lamp All Screens/Check 2 W bit 1.01 _ Stop Bit Button/ Bit Lamp All Screens/Check 2 W bit 1.02 _ Close Bit Button/ Bit Lamp All Screens/Check 2 LW.B 10.0 Texts on screen flash Bit Lamp Stop C 0 Counter address Level Meter, Number Display Wait, Check 3 T 0 Timer address Number Display Check 3 D 0 Switch Screens PLC Control - D 11 Output Screen No.
PLC Control - CIO bit 0.03~0.06 _ (See the following table) Bit Lamp Check 1 Equipments Contactors Addresses Vehicle sensor SEN1 0.03 Light sensor SEN2 0.04 Upper limit LS LS1 0.05 Lower limit LS LS2 0.06 Motor for opening control (Rise motor) MO1 100.00 Motor for closing control (Down motor) MO2 100.01