NERLITE Edge-to-Edge Backlights Configuration Guide If using this product in strobe mode with an NL-2XX Series Lighting Controller, refer to the warning on the back of this document. Hardware Required Item 1 2 3 4 1 3 4 12V.

1.4A (UNFUSED) POWER OUTPUT 1 2 2 4 Figure A Edge-to-Edge Backlight Series Illuminator with power supply Figure B Edge-to-Edge Backlight Series Illuminator with NL-200 and power supply P/N 83-230006-02 Rev D Continuous Operation Strobe Operation Part Number Description Continuous Curren t Strobe Current Fan Cooled No Controller Required (Can be Connectet Directly to 24VDC) NL-2XX Optional (Used only if Intens and/or Ethernet Control Is Des ity ired) NL-2XX (Required) Connection Notes Reference Number (See the Connection Notes on back of page) NER-011659300G BL 47X59 Red Continuous 93mA NA Figure A Figure B 7 NER-011659301G BL 47X59 Red Strobe NA 2.67A Figure B 7 NER-011659310G BL 47X59 White Continuous 201mA NA Figure A Figure B 7 NER-011659400G BL 71X88 Red Continuous 170mA NA Figure A Figure B 7 NER-011659401G BL 71X88 Red Strobe NA 5.01A Figure B 7 NER-011659410G BL 71X88 White Continuous 330mA NA Figure A Figure B 7 NER-011659500G BL 100X100 Red Continuous 155mA NA Figure A Figure B 7 NER-011659501G BL 100X100 Red Strobe NA 4.99A Figure B 7 NER-011659510G BL 100X100 White Continuous 350mA NA Figure A Figure B 7 NER-011659600G BL 50X200 Red Continuous 155mA NA Figure A Figure B 7 NER-011659601G BL 50X200 Red Strobe NA 4.99A Figure B 7 NER-011659610G BL 50X200 White Continuous 350mA NA Figure A Figure B 7 Description Part Number Edge-To-Edge Backlights NER-011659XXXG Power Supply DSP60 24VDC 2.5A DIN Mount NER-011504100 NL-200 Series Lighting Controller 98-000152-0X Cable 4 Pin M12 Female To Flying Leads NER-030029100 - 12V.

+ POW - POW + INP

Стр. 1

NERLITE Edge-to-Edge Backlights WARNING! When connecting a strobe light to an NL-2XX Series Lighting Controller, you must set the current rating to 10% of the current specified for the light in this document. The NL-2XX Series Controller allows the operator to set the brightness (current) to 1000% in strobe mode. By setting the initial current rating to 10% of the light’s specified current, a brightness setting of 1000% results in the light receiving 100% of its rated current. This will provide maximum light output without damaging the light. Note: Certain lights require both channels of the NL-2XX Series Lighting Controller.

Channel 1 and Channel 2 may have different current specifications on some models. Be sure each channel is set correctly as specified in this document. General Notes: 1. Those lights that do not require a controller require 24VDC +/- 1%. 2. The NL-2XX series controllers require 24 to 48VDC. 3. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions. 4. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions. 5.

All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating. 6. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’ manual for pulse width and duty cycle limitations under various conditions. Connection Notes: 1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground. 2.

Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the nega- tive(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 3. Connect the lead labeled “V+1” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “GND1” to the negative(-) output terminal of channel 1 on the NL-2XX series controller.

Connect the lead labeled “V+2” to the positive(+) outpt terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “GND2” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Shield” to chassis ground 4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power supply or controller. Connect the cable’s braided shield to chassis ground. 5. Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller.

Connect the lead labeled “DOAL GND” to the nega- tive(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 6.

Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used. Copyright ©2019 Omron Microscan Systems, Inc.

www.microscan.com AC Power Cord US NER-030028300 Power Cord For Power Supply AC Power Cord EU NER-030028400 Power Cord For Power Supply AC Power Cord UK NER-030028500 Power Cord For Power Supply CBL, M12F-FLYING LEADS, 4.5M [15FT] NER-030029100 Connect Backlight To Power Supply Or Controller

Стр. 2