23 4 [Display Parameter Group] becomes [Port 2: Protocol Macro Setting]. The settings of [Port 2: Protocol macro setting] are displayed. Confirm that [Port 2: Arbitrary setting] is [Arbitrary setting] and that the other items are the same as the settings in section 6.1. * If the settings differ, change them to the values in the pull-down menu. If you change the value, click Apply. 5 Double-click [I/O Map] under "Configurations and Setup" in the Multiview Explorer. The [I/O Map] tab appears and the unit parameters are displayed. 6 Make sure that the beginning of the data in the [Variable] area of the [I/O Map] screen is [J01], and that the [Variable type] area is set to [Global Variable].
* If the settings are different, select [Create Device Variable] from the right mouse button menu with [CJ1W-SCU22] selected as shown in the right figure. 7 Double-click "Task Settings" under "Configurations and Setup" in the Multiview Explorer.