Step 3 Place the printer top-down with the infrared port facing forward. Step 4 Remove the two mounting screws from the duplex cover, disengage the duplexer release lever from the refeeder assembly, and remove the lever. 21 Figure 132. Remove the duplex cover Step 5 Unplug the refeeder three-pin harness. Step 6 Remove the five mounting screws (callout 1) from the tray 2 pickup roller and refeeder assembly. Step 7 Lift off the tray 2 pickup roller and refeeder assembly. 21 Figure 133. Remove tray 2 pickup-roller and refeeder assembly 154 Chapter 6 Removal and replacement C7058-90936