Table 31. Fatal error secondary codes (continued) Table 32. Accessory error codes Table 33. Accessory errors secondary codes 190 Chapter 7 Troubleshooting C7058-90936 Control-panel light pattern Fatal error secondary message Status log code Recommended action RAM controller error (65) 40065 Turn the printer off, then turn it back on. Replace the formatter. Miscellaneous interface hardware error (67) 40067 Check the I/O connections. Verify that the cable is IEEE-1284 compliant (if applicable). Control-panel light patterns Accessory error message Status log code Recommended action An error has occurred with either the EIO port or the DIMM (memory) slots.
Press GO and JOB CANCEL simultaneously to view the secondary information. See table 29, “Continuable attention error secondary codes” on page 184 and table 33, “Accessory errors secondary codes” on page 190. Control-panel light patterns Accessory secondary error message Status log code Recommended action EIO port error Turn the printer off and reseat the EIO accessory. Turn the printer on. Replace the formatter.