PanelScan Integration Guide Setting Up the System The system must be pre-configured for PanelScan Standard or PanelScan Wide. To do this: • Start PanelScan. • Ignore any error messages and select the menu item Config , and then System Configuration . • The System Settings dialog will appear: • Select the number of cameras in the system. Use 1 for PanelScan Standard, and 2 for PanelScan Wide. • Next, enter the serial number for each camera. The serial numbers can be seen on the labels on the back of the cameras. Camera 1 is the camera on the left if looking down at the top of the board in the direction of board movement. • Click the Set As New System Defaults button.
This will write system settings data into a systemsettings.ini file in the C:\PanelScan\systemsettings directory. All new vision jobs will use this data as the default. • Exit and restart PanelScan. It should now recognize the cameras. All parameters in the System Settings dialog will act as default settings for any new PanelScan job that is created. Note: The 10 Work Order Label fields are described in the Work Order Info section. Camera 2 Overlap , Camera 2 Y-Shift , Exposure Time , Gain , Search Width +/– and Search Height +/– are described in the Vision Setup section. The parameters in this dialog are defaults for new jobs.
If these parameters are changed in the actual job configuration dialogs, the job configuration settings will take precedence. 13 Copyright © 2019 Omron Microscan Systems, Inc.