omron — PanelScan Details

PanelScan Integration Guide Non Grid Layout Non Grid Layout is useful for when boards are not in a row and column configuration. This option allows you to point to each board individually during the teach process. In this field, simply enter the number of boards on the panel. Rows and columns can be added manually. This allows you to set the order of the ROI in any orientation and the UI will show a grid during run time. • Number of Boards on Panel – This is the number of boards on a non-grid panel from 1 to 160 . • Manually Add Rows Cols – PanelScan sets the location and sizing of rows and columns based on where you click in the teaching setup.

The option to add rows and columns manually is intended for cases in which the layout is grid-like but doesn’t conform to the rigid structure of standard rows and columns. You will still manually add each ROI, but the UI will track the ROI as Row 1 Col 1, Row 2 Col 1, etc. The UI on the left side of the main screen will show the grid. Enable Panel ID Check the Enable Panel ID box when there is a singular Panel ID that must be read in addition to the labels on each board. During panel training, you will be asked to click on the location of the Panel ID. During runtime, the Panel ID is included with each panel report record.

Enable Fiducial Find Enable Fiducial Find adds additional Find and Train functionality related to fiducial marks on boards. Contact Omron Microscan helpdesk for additional information about this feature. 22 Copyright © 2019 Omron Microscan Systems, Inc.