Model Numbering

TECHNICAL DATASHEET PMT2 Panel Mount Power Supply PMT2 50W series / PMT- V50W2B PMT2 Highlights & Features Household appliance approvals for pollution degree 3 to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16 Universal AC input voltage range No load power consumption Low profile design : 30mm height Over voltage category III Conforms to harmonic current IEC/EN 61000-3-2, Class A High MTBF > 700,000 hrs per Telcordia SR-332 Safety Standards CB Certified for worldwide use Model Number: PMT- V50W2B Unit Weight: 0.176 kg (0.389 lb) Dimensions (L x W x D):

99 x 82 x 30 mm (3.9 x 3.23 x 1.18 inch) General Description PMT 2 nd generation (PMT2) power supplies is designed with low profile, offers universal input with nominal output voltage. The highly efficient convection cooling construction can operate from -30°C to 70°C. The single output is specifically designed with compact and competitively priced for household electrical appliances safety approvals to pollution degree 3 as well as including IEC/EN 60335-1, IEC/EN 61558-2-16, IEC/EN/UL 60950-1. Model Information PMT2 Panel Mount Power Supply Model Numbering *Options 1 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev.

02) Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V50W2B☐☐ 90-264Vac 12Vdc 4.2A PMT-24V50W2B☐☐ 24Vdc 2.2A CC code* PM T – □V 50W 2 B □ □ Panel Mount Product Type T – Enclosed Output Voltage 12 – 12V 24 – 24V Output Power Single Phase with Low Profile Family Code: B With No PFC Connector Type A – Terminal Block Blank – Without connector cover

Стр. 1

Output Ratings / Characteristics*

TECHNICAL DATASHEET PMT2 Panel Mount Power Supply PMT2 50W series / PMT- V50W2B Specifications Input Ratings / Characteristics Output Ratings / Characteristics* *For power de-rating from > 50°C to 70°C, see power de-rating on page 3. **PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1µF ceramic capacitor & 47µF electrolytic capacitor . PSU need to burn in > 5 minutes when AMB ≤ 0 2 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev.

02) Model Number PMT-12V50W2B☐☐ PMT-24V50W2B☐☐ Nominal Input Voltage 100-240Vac Input Voltage Range 90-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current 0.95A typ. @ 115Vac, 0.55A typ. @ 230Vac Efficiency at 100% Load @ 230Vac 86% typ. 88.3% typ. No Load Power Consumption 0.2W typ. @ 230Vac Max Inrush Current (Cold Start) 45A typ. @ 230Vac Leakage Current Nominal Output Voltage 12Vdc 24Vdc Factory Set Point Tolerance 12Vdc ± 1% 24Vdc ± 1% Output Voltage Adjustment Range 10.8-13.2Vdc 21.6-26.4Vdc Output Current 4.2A 2.2A Output Power 50.4W Max. 52.8W Max. Line Regulation Load Regulation PARD** (20MHz) Rise Time 15ms typ.

@ 115Vac & 230Vac (100% load) Start-up Time 1,000ms typ. @ 115Vac 500ms typ. @ 230Vac (100% load) Hold-up Time 15ms typ. @ 115Vac, 70ms typ. @ 230Vac Dynamic Response (Overshoot & Undershoot O/P ± 10% @ 230Vac input, 0-50%, 5-100%, 50-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) Start-up with Capacitive Loads 8,000µF Max 4,000µF Max

Стр. 2

Protections

TECHNICAL DATASHEET PMT2 Panel Mount Power Supply PMT2 50W series / PMT- V50W2B Mechanical Environment Protections *PE: Primary Earth 3 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev.

02) Case Chassis Aluminium Case Cover SGCC Dimensions (L x W x D) 99 x 82 x 30 mm (3.9 x 3.23 x 1.18 inch) Unit Weight 0.176 kg (0.389 lb) Indicator Green LED (DC OK) Cooling System Convection Terminal M3.5 x 5 Pins (Rated 300V/15A) Wire AWG 22-12 Noise (1 Meter from power supply) Sound Pressure Level (SPL) Surrounding Air Temperature Operating -30°C to +70°C (-40°C Cold Start) Storage -25°C to +85°C Power De-rating > 50°C de-rate power by 2% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 5,000 Meters (0 to 16,400 ft) Shock Test Non-Operating IEC 60068-2-27, Half Sine Wave:

50G for a duration of 11ms, 3 shocks for each 3 directions Operating IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. Vibration Non-Operating IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction Operating IEC 60068-2-6, Sine Wave:

20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) Over Voltage Category III (Compliance to EN 61558, EN 62477-1 with 2000 meters altitude) Pollution Degree 3 Overvoltage 13.2V-17.4V SELV Output, Latch Mode 26.4V-33.6V SELV Output, Latch Mode Overload / Overcurrent 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature Latch Mode Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection (Must be connected Earth terminal with mark on metal side surface.)

Стр. 3

EMC

TECHNICAL DATASHEET PMT2 Panel Mount Power Supply PMT2 50W series / PMT- V50W2B Reliability Data Safety Standards / Directives EMC 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) 4 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2018, Rev.

02) MTBF > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C) Expected Cap Life Time 10 years (230Vac, 50% load @ 40°C) Safety Entry Low Voltage SELV (EN 60950-1) Electrical Safety TUV Bauart UL/cUL recognized CB scheme CCC EN 62368-1, EN 60950-1, EN 60335-1, EN 61558-1/-2-16 UL 62368-1, and CSA C22.2 No.

62368-1 IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 GB4943 CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.75KVac Input to Ground 2.0KVac Output to Ground 0.5KVac Emissions (CE & RE) CISPR 32, EN 55032 Compliance to EN55014-1, FCC Title 47: Class B Immunity EN 55024, EN 55035, Compliance to EN55014-2 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge:

8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode4): 2kV Differential Mode5): 1kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic IEC 61000-4-8 Fields Level 4 Criteria A1) 30A/Meter Voltage Dips and Interruptions IEC 61000-4-11 100% dip; 1 cycle, Criteria B 2) 40% dip; 10 cycle, Criteria C 3) 70% dip; 25 cycle, Criteria C 3) 100% dip; 250 cycle, Criteria C 3) Harmonic Current Emission IEC/EN 61000-3-2 Class A