omron — 6. Test Operation

4.4. Modifying Program If an error occurs, correct the error while referring to the CP2E CPU Unit User’s Manual , the CP1E CPU Unit User’s Manual , and the CP1E/CP2E Instructions Reference Manual . Precautions for Correct Use Some errors may not be detected by the above-mentioned check with Compile . Check the entire program to ensure there are no problems with the system, and modify as necessary. 4.5. PLC Setup Changes Depending on the CP2E model being used for replacement, the CP1E PLC Setup settings may not be transferred. Open the PLC Setup settings for the CP2E, and configure the settings manually. Make sure that the PLC Setup settings have been changed correctly.

When changing models as follows, the PLC Setup settings will be transferred when the PLC model is changed. *: The PLC Setup settings are not transferred even when changing from the CP2E to a different model. 5. Transferring Data Transfer the programs, settings, and data that have been converted or modified to the CP2E CPU Unit via USB port or Ethernet port. Set the clock if the timer function will be used. 6. Test Operation Turn on the power and confirm operation is correct before starting actual operation. Precautions for Correct Use After replacement, please perform trial operation before starting actual operation and check that the system operates correctly.

If the wiring or settings are not configured correctly, the system may malfunction. 14 Model being replaced: CP1E Model used for replacement: CP2E Transferring PLC Setup settings CP1E-E CP2E-E Carried over CP2E-S, CP2E-N Cannot be carried over CP1E-N CP2E-E Cannot be carried over CP2E-S, CP2E-N Carried over Models other than CP1E CS/CJ/CP1H/CP1L CP2E-E, CP2E-S, CP2E-N Cannot be carried over