oven — 7.2 Setting the operating mode of the counter

Table 7.1 (continued) 47 Name of the mode Input functions Principle of operation Illustration Input 3 - reset Input 4 - block • if both setpoints have the same sign, counter does not reset after reaching lesser (by module) value. Otherwise, corresponding output is switched each time counter reaches this setpoint, regardless of the direction of the count t1, t3, t5 – moments of the decrease in the value of the counting register (impulse appears at the counting input 2); t2 – moment of switching of output 2 in case of coincidence of values of the counting register and setpoint 2; t4 – moment of switching of output 1 in case of coincidence of values of the counting register and setpoint 1