2 1 LT000070 Renewing fuel filter Cleaning inductive pulse generator at rear wheel drive Inspection III Inspections I, III, IV • If necessary, reduce fuel level with pump until fil- sure recesses (arrows) in gasket are fitted in correct position. • Release securing screw (1). • If necessary lever out inductive pulse generator and clean with rag. X Tightening torque: Inductive pulse generator at rear wheel....... 2.5 Nm 00.13 ter is clear. • Loosen hose clip (1) and shift towards filter. • Detach line and remove filter together with line from the fuel tank. • Change fuel filter. L Note: Note direction of fuel flow on filter. 1 • Reconnect line to pump.
• Install in the reverse order of removal. L Note: Gasket (2) must not close off the overflow hole. En- LT000080 LT000080