A power interruption on the Secondary appliance results in no loss of connectivity with AMRs and MobilePlanner. You should: l Verify that MobilePlanner and AMRs are connected to the Fleet IP address. l Review the job queue status in MobilePlanner and verify the status of AMRs to make sure that no jobs are incomplete. l Restore power to the Secondary appliance. Autosync will be restarted if it was running when the power was interrupted. Fleet operations should be unaffected. If both Autosync appliances are affected by a power interruption, they both behave as described in: Power Interruptions on a Standalone EM2100 on page 22:
l All fleet operations are terminated during the power interruption. l Normal Active Autosync operation resumes automatically after you restore power to both appliances. l The Primary EM2100 saves its job queue status and recovers the queue automatically after it restarts. Autosync will reconnect automatically when power is restored. 3.3 Set the IP Address on a Client PC's Network Adapter Use the Maintenance Ethernet port to connect a client PC to the SetNetGo operating system. IMPORTANT: You must assign a static (fixed) IP address. Do not use a DHCP server. Configure the network adapter IPv4 address on the Client PC as follows: 1.
Connect a CAT 5 Ethernet cable from the client PC’s Ethernet port to the Maintenance Ethernet port on the EM2100 appliance. 2. In the command field on the Windows taskbar, enter the following command to open the Network Connections dialog: ncpa.cpl 3. Open the network properties of the PC ethernet network adapter used to connect to the Maintenance Ethernet port on the EM2100 appliance. 4. Double-click TCP/IPv4 to open the Internet Protocol properties dialog. 5. Enter as the IP address: 1. 2. 3. 5, or any IP address in the range 1. 2. 3. 0 to 1. 2. 3. 255, excluding 1. 2. 3. 4. (this is reserved for the Maintenance port). 6. Enter as the subnet mask: 255. 255. 255. 0. 7.
Press OK to close the Internet Protocol dialog, and then press OK to close the Ethernet Adapter dialog. In future, you can use the Maintenance Ethernet port for emergency access to the Appliance at IP address 1.2.3.4. (For example, if you lose the password or if there is a network IP address conflict.) 3.4 Connect Your PC to SetNetGo on the EM2100 SetNetGo enables you to configure and manage EM2100 and AMR settings. This section describes how to access SetNetGo through the Maintenance port to perform initial 20569-020 Rev. A Fleet Operations Workspace Core User's Guide 23