7.3. Safety Controller Setup Set up the Safety Controller. The Sysmac Studio is used for the Safety Controller setup, please install before proceeding.. 7.3.1. Hardware configuration and IP address Settings Configure the hardware of the Safety Controller and set the IP address using the hardware switches. Precautions for Correct Use Make sure that the power supply is OFF when before setting up. If it is ON, the settings described in the following steps and subsequent procedures may not be applicable. 12 1 Make sure that Safety Controller is powered OFF. 2 Connect Safety CPU Unit to Safety Controller Communication Control Unit.
Communication Control Unit Check the positions of Rotary Safety Rotary switches switches and Built-in CPU Unit EtherNet/IP ports. PORT1 End Cover PORT2A PORT2B Built-in EtherNet/IP ports 3 Set the IP address (IP address Rotary switches 2) of Built-in EtherNet/IP port (PORT2A / PORT2B) to 192.168.250.1 in the following way. Set Rotary switches for IP address 2 as follows: ・x16: 0 IP address 2 ・x1: 1 *The first 3 octets of the IP address 2 are fixed to 192.168.250 (default). The last octet is a value that is set by Rotary switches. x16 x1