HP — Cartridge carousel assembly

1 2 3 5 4 Figure 6-66 Cartridge carousel replacement - face-down delivery rod (4 of 6) 22 Remove the door switch assembly (see “Top cover switch assembly” on page 161). 23 Remove the carousel grounding plate (see Figure 6-66, callout 2) and the carousel position plate from the carousel mouting plate (see Figure 6-66, callout 3) on the printer’s right side. 24 Disconnect the cables going to PS-11 and the Continuous Toner Level Sensor (CTLS) assembly, and remove the CTLS (see Figure 6-39). 25 Using a flat-bladed screwdriver, remove the clip securing the grounding cam and lift off the grounding cam (see Figure 6-66, callout 4). 26 Remove the drum bushing assembly (see Figure 6-66, callout 5).

27 Remove the left-side carousel mounting plate. 28 Remove all visible screws from the carousel mounting plate on the printer’s right side (see Figure 6-67). Figure 6-67 Cartridge carousel replacement - right-side carousel mounting plate (5 of 6) 202 Removal and replacement C7085-90921