Chapter 3 Basic Operation and Trial Run 3.1 Keyboard Layout and Function Specification (optional) SI30 Solar Pump Inverter Manual Keyboard Appearance Key Function 11 Key Name Function Menu key Enter menu while standby or running. Press this key to return back while modifying parameters. While standby or running, press for 1 sec to enter monitoring interface. Confirm/modify key Press to modify parameter while in menu interface. Press again to confirm after modifying. While standby or running, press to change LED monitoring items at stop. Up/down key Select parameter group in menu interface. Modify parameter while in modify interface.
Modify given frequency, PID, given torque or magnetic powder clutch given torque while at standby or condition monitoring state. Shift key Select digit of function no modified by up/down key, Select parameter digits modified by up/down key. Change LED monitoring items while standby or running. Forward run key While run/stop is controlled by keyboard, press this key, the inverter forward rotate and the indicator is always on. While reverse, the indicator sparks. Jog/reverse key This key function can be defined by parameter [F4.02]. Press it, machine reverses and indicator is off if this key is defined as REVERSE. Machine will jog and indicator is on if this key is defined as JOG.