4. Solar pump inverter, in a certain output frequency range, can meet the mechanical resonance of the SI30 Solar Pump Inverter Manual load equipment. To avoid it, you can set up jumping frequency. 5. As output voltage of the inverter is pulse-wave type, if there is capacity which can improve power factor or pressure-sensitive resistance which used for thunder-proof in the voltage output side, the solar pump inverter will break off or its parts will be damaged, so it is necessary to dismantle them.
Moreover, it is proposed not install switch parts like air switch and contactor (if it is necessary to install switch on output side, please make sure the output electricity of solar pump inverter is zero when the switch is working) 6. At over 1,000 meters altitude, the inverter’s heat dissipation function worsened due to the thin air, it is necessary to use less. 7. The inverter output voltage is pulse wave type. If using digital multi-meter measurement, deviation of the reading will be great. And the deviation is different by using different type of digital multi-meter. Under normal circumstances, while RMS 380V, digital multi-meter reading is around 450V. 8.
Solar panel can be connected in series or parallel. For rated voltage 380V controller, we suggest solar panel open circuit voltage should be between 620~ 750V. 1.4 Technical Specification 1.5 Cautions in Disposal When you dispose solar pump inverter, please pay attention to: 1. Electrolytic capacitor: the electrolytic capacitor of main circuit or the printing plate may explode when they are burned. 2. Plastic: plastic incineration may generate toxic gases. 3. Dispose method: please dispose as industrial waste.
4 Solar pump inverter power(KW) Pump Max solar power input (KW) Max DC input voltage (V) Recommend Voc voltage (V) Rated output current (A) Output frequency (Hz) Rated power (KW) Rated voltage (V) SI30-D1 series, DC90-400V input,3 phase 110-230VAC output, MPPT voltage range 90-400VDC,for AC110V pumps 0.75 0.75 110 1.0 400 175~380 7A 0-320 1.5 1.5 110 1.95 400 175~380 10A 0-320 SI30-D3 series,DC150V-450V input,3 phase 220-240VAC output, MPPT voltage range 150-450VDC, for AC220V pumps 0.75 0.75 220 1.0 450 360~430 4A 0-320 1.5 1.5 220 1.95 450 360~430 7A 0-320 2.2 2.2 220 2.86 450 360~430 10A 0-320 SI30-D5 series,DC300V to 850V input,3 phase 230-460VAC output, MPPT voltage range 300-800VDC,for AC380V pumps 0.75 0.75 380 1.0 850 620~750 2.5 0-320 1.5 1.5 380 2.2 850 620~750 3.7 0-320 2.2 2.2 380 3.3 850 620~750 5.0 0-320 4 3.7 380 5 850 620~750 10 0-320 5.5 5.5 380 8 850 620~750 13 0-320 7.5 7.5 380 10 850 620~750 17 0-320 11 11 380 14.3 850 620~750 25 0-320