Specifications * For an average count of 100. The value is ± 2 μ m for an average count of 100 (Sensing objective: white ceramic substrate). Laser Label Description Laser Radiations : Class 2 Product Maximum Output: Pulse Duration: 0.5ms max. Wave Length:

635nm, IEC 60825-1:2014 16 Laser Displacement Sensing Method Triangulation Model Name LD-040N LD-080N LD-150N Reference Distance 40 mm 80 mm 150 mm Measurement Range ± 10 mm ± 25 mm ± 60 mm Interface Digital IO / Modbus Communication (RS-485) Spot Size 50 x 15 µm 95 x 25 µm 168 x 40 µm Light Source Laser CLASS 2 Input Voltage 12 ~ 24 V ± 10% DC Repeatability* 2 µm 5 µm 15 µm Linearity ± 0.1% ± 0.1% ± 0.1% Sampling Rate 1 ms Indicator Laser ON: blue, Measurement range: green, Out of measurement range: orange, DO: yellow, DI:

red Protection Circuit Protection against reverse power connection, output overcurrent, power supply surge, output surge Operating Temperature 10 ℃~ 50 ℃ Storage Temperature -20 ℃~ 75 ℃ Ambient Humidity 30 ~ 85% Enclosure Rating IP67 Ambient Light Resistance 5,000 lx or less Vibration Resistance 10 ~ 55 Hz, 1.5 mm, 3 axes for 2 hours Insulating Resistance 20 MΩ or more (500 V DC) Withstand Voltage 1,000 V 50 / 60 Hz 1min AC Certifications CE Materials Optical window: PMMA; Case: Aluminium; Cable: PVC Cables M8 Connector (8 Pin) Dimensions 55 × 42 × 24 mm Weight 113 g