Technical Specifications *¹ Dry and clean gas without dirt and oil *І Flow transfers into value below. Standard volume std (pre-setting): 20 ° C, AP 101.3 kPa * 3 Please ensure both sides are connected to pipe when operating. If one side is not connected, pressure will decrease and lead to inaccurate measurement 44 Input Power Voltage range 24 V ± 10 % non-isolation DC Power consumption 24 V: - Voltage output and RS-485 models: max. 0.96 W - Current output model: max. 1.2 W Gas Flow Measurement Measurement range*² 2 ~ 200 L / min*¹ Measurable gas Air, N, Ar, CO (varies in different models) 2 2 Operation pressure 0 ~ 0.75 MPa Max. durable pressure 1 MPa Pressure-related inaccuracy ± 5 % F.S.

(0 ~ 0.75 MPa) entire process The process is based on pressure 0.35 MPa. Pressure can also lead to innaccuracies other than measurement inaccuracy.*3 Measurement accuracy ± 3 % F.S. entire process Temperature-related inaccuracy ± 5 % F.S. (0° C ~ 50°C) entire process The process is based on temperature 25 °C. Temperature can also lead to innaccuracies other than measurement inaccuracy Functions Peak volume display / accumulated volume display / reverse display / zero adjustment / button lockup / energy-saving mode / percentage (analog output) / delay decision Display Flow volume display Max.

4 digits for peak volume, 8 digits for accumulated volume Display modes 2 colors (red and green) display available based on different modes Output Output terminals Built-in 2 NPN or PNP transistor digital outputs and 1 analog output (varies in different models) Input terminals Built-in 1 digital output, shares terminal with 2nd output Output form NPN: max. durable pressure 30V / 100mA, residual voltage 1.5 V PNP: max. durable pressure 30V / 100mA, residual voltage 1.5 V Output (varies in different models) Analog voltage: 1 ~ 5 V, min. output load resistance 50 kΩ Linear inaccuracy Analog current: 4 ~ 20 mA, max.

output load resistance 300 Ω Linear inaccuracy Digital RS-485 Response time 50 ms / 100 ms / 500 ms / 1 secs / 2 secs Gas Nozzle Size C8 Fast connection port Ø8 (8 mm diameter pipe connectable) Cable Specifications Connector Standard 2 m cable included Operation Temperature 0 °C ~ 50 °C Storage Temperature -10 °C ~ 60 °C Operation Humidity 35 % ~ 85 % RH (Non-condensed)