Chapter 7:
sDIO Module 7.5 Installing Multiple sDIO Modules Recommended Configurations OK LINK SF 1.1 1.2 XDC1 XDC2 X3 IEEE-1394 X1 X2 X4 - + - + 24V 0.5A *S/N 3563-XXXXX* SC-DIO sDIO Module #4 Block 19 Input Signals 1233 to 1264 Output Signals 0233 to 0264 1394 cable 24 VDC cable 1.1 1.2 XDC1 XDC2 X3 IEEE-1394 X1 X2 X4 *S/N 3563-XXXXX* SC-DIO sDIO Module #3 Block 18 Input Signals 1201 to 1232 Output Signals 0201 to 0232 OK LINK SF - + - + 24V 0.5A 1394 cable 24 VDC cable Block 17 (default) Input Signals 1065 to 1096 Output Signals 0065 to 0096 OK LINK SF 1.1 1.2 XDC1 XDC2 X3 IEEE-1394 X1 X2 X4 - + - + 24V 0.5A *S/N 3563-XXXXX* SC-DIO sDIO Module #2 1394 cable 24 VDC cable OK LINK SF 1.1 1.2 XDC1 XDC2 X3 IEEE-1394 X1 X2 X4 - + - + 24V 0.5A *S/N 3563-XXXXX* SC-DIO sDIO Module #1 Block 16 (default) Input Signals 1033 to 1064 Output Signals 0033 to 0064 1394 cable 24 VDC cable SmartController EX Motion Controller 1394 cable 24 VDC from Customer-supplied power supply Figure 7-9.
Using Multiple sDIO Modules NOTE: When adding additional sDIO modules, each additional sDIO module must be grounded per all applicable regulations. Configuring Multiple sDIO Modules Up to eight sDIO modules can be added to a system. The first sDIO module occupies the first 4 bytes of block 16. The second sDIO module uses block 17. Additional sDIO modules need to be configured. Refer to Modifying the Default sDIO Configuration on page 62, and the values in the figure Input/Output Block Configuration for Optional sDIO Modules on page 66. SmartController EX User’s Guide, 11069-000 Rev. F Page 67 of 92