omron — Руководство по эксплуатации STC HD133 HD93 Series - цветные камеры (EN)

No.16S058-01 b. COMM 1) Port Setting Set up the communication port. a) Port Please select the COM port that connects to the communication port of the camera. Please check the COM port number at the device manager. b) Baud rate The baud rate of the PC selects automatically to match to the baud rate of the camera. The baud rate of the camera is 38,400bps. c) Change camera baud rate Select the operation if the baud rate of the camera is not 38,400bps ShowDialog : The dialog is displayed. ChangeSilentry : The baud rate of the camera changes to 38,400bps automatically. DontChange : The baud rate of the camera does not change.

d) Debug Mode The details of the communication data can review by “Debug View” software when “Debug Mode” is selected. 2) Read All The current camera settings receive from the camera. 3) DSP -> EEPROM The current DSP preset settings save to the EEPROM. 4) EEPROM -> DSP The current DSP preset settings load from the EEPROM. 5) uCOM -> EEPROM The current uCOM settings save to the EEPROM. 6) EEPROM -> uCOM The uCOM settings load from the EEPROM. 21/49 STC-HD133 Series (STC-HD133DV / STC-HD133SDI) / STC-HD93 Series (STC-HD93DV / STC-HD93SDI) Users guide