2.0 Installation in the Rack The board is configured to be mounted into a VMEbus rack at any one of the slots 2-21. A reset generator has to be included in another slot. Caution: A) The VMEbus rack has to include a Jl and a J2 backplane. B) Switch power off before installing the board to avoid electrical damages to the components. C) The board has the be plugged in and the screws of the front panel must be turned on to guarantee proper installation. D) No connections are allowed on the P2 backplane on rows A and C (i.e. VMXbus or VSBbus connection). 2.1 Power On If the board is installed correctly, the following sequence will take place: 1) Green RUN LED lights up.
2) During SYSRESET, HALT LED is red. 3) After SYSRESET goes inactive, the HALT LED turns green and the red SYSFAIL LED turns on. At this time the SYSFAIL signal on the VMEbus is also activated. 4) The onboard firmware starts execution of the onboard self test, which takes about 30 seconds. The status information that is given on the front panel LEDs Sl-S4 is described in Chapter 2.2. 5) When the self test is complete and if no errors have occurred, the SYSFAIL LED turns off and the SYS68K/ISCSI-l is ready for operation. If any errors are detected during self test, the LED S4 turns on and the LEDs Sl-S3 show an error code. Please refer to the Software User's Manual for details. 2-1