omron — 2-step Acceleration/Deceleration Function

4-2 Function Mode 2-step Acceleration/Deceleration Function This function changes the acceleration/deceleration time during such operations. 4 Functions * To switch to the 2nd control, allocate 08 (SET) to the multi-function input terminal and then turn it on. •The acceleration/deceleration time can be switched via the multi-function input terminal or automatically with an arbitrary frequency. •To switch via the multi-function input terminal, allocate 09 (2CH) to it.

(Example 1) When A094/A294 is set to 00 (Example 2) When A094/A294 is set to 01 FW FW 2CH Acceleration 2 Deceleration 2 Acceleration 2 Deceleration 2 Acceleration 1 Deceleration 1 A095/A295 A096/A296 Output frequency Output frequency Deceleration 1 F002/F202 A092/A292 A093/A293 F003/F203 F002/F202 A092/A292 A093/A293 F003/F203 4-24 Parameter No. Function name Data Default setting Unit A092 Acceleration time 2 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 15.0 s * A292 2nd acceleration time 2 15.0 s A093 Deceleration time 2 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 15.0 s * A293 2nd deceleration time 2 15.0 s A094 2-step acceleration/ deceleration selection 00:

Switched via multi-function input 09 (2CH) 01: Switched by setting 00 ⎯ * A294 2nd 2-step acceleration/ deceleration selection 00: Switched via multi-function input 09 (2CH) 01: Switched by setting 00 ⎯ A095 2-step acceleration frequency 0.0 to 400 0.0 Hz * A295 2nd 2-step acceleration frequency 0.0 to 400 0.0 Hz A096 2-step deceleration frequency 0.0 to 400 0.0 Hz * A296 *2nd 2-step deceleration frequency 0.0 to 400 0.0 Hz Related functions F002, F003, F202, F203, C001 to C005 eratio n 1