omron — 7-1 Standard Specification List

7-1 Standard Specification List „ 3-phase 400-V Class 7 „ 1/3-phase 200-V Class Specifications 7-2 Item 3-phase 400-V class Model name (3G3JX-) A4004 A4007 A4015 A4022 A4037 A4055 A4075 Applicable motor capacity *1 kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 HP 1/2 1 2 3 5 7.5 10 Rated output capacity (kVA) 380 V 0.9 1.6 2.5 3.6 5.6 8.5 10.5 480 V 1.2 2.0 3.1 4.5 7.1 10.8 13.3 Rated input voltage 3-phase (3-wire) 380 V -15% to 480 V +10%, 50/60 Hz ±5% Built-in filter Radio noise filter Rated input current (A) 2.0 3.3 5.0 7.0 11.0 16.5 20.0 Rated output voltage *2 3-phase:

380 to 480 V (for input voltage) Rated output current (A) 1.5 2.5 3.8 5.5 8.6 13.0 16.0 Weight [kg] 1.5 2.3 2.4 2.4 2.4 4.2 4.2 Cooling method Self-cooling Forced-air-cooling Braking torque At short-time deceleration*3 At capacitor feedback Approx. 50% Approx. 20% to 40% Approx.

20% DC injection braking Injection braking frequency/time, braking force variable, frequency control available Item 1/3-phase 200-V class Model name (3G3JX-) AE002 AE004 AE007 AE015 AE022 Applicable motor capacity *1 kW 0.2 0.4 0.75 1.5 2.2 HP 1/4 1/2 1 2 3 Rated output capacity (kVA) 200 V 0.4 0.9 1.3 2.4 3.4 240 V 0.5 1.0 1.6 2.9 4.1 Rated input voltage 1/3-phase 200 V -15% to 240 V +10% 50/60 Hz ±5% Built-in filter None Rated input current (A) 1.8 3.4 5.2 9.3 13.0 Rated output voltage *2 3-phase:

200 to 240 V (for input voltage) Rated output current (A) 1.4 2.6 4.0 7.1 10.0 Weight [kg] 0.8 0.9 1.5 2.3 2.4 Cooling method Self-cooling Forced-air-cooling Braking torque At short-time deceleration*3 At capacitor feedback Approx. 50% Approx. 20% to 40% DC injection braking Injection braking frequency/time, braking force variable, frequency control available