2-1 Installation „ Transporting, Installation, and Wiring •Do not drop or apply strong impact on the product. Doing so may result in damaged parts or malfunction. •Do not hold by the front cover, but hold by the fins during transportation. •Do not connect an AC power supply voltage to the control input/output terminals. Doing so may result in damage to the product. •Be sure to tighten the screws on the terminal block securely. Wiring work must be done after installing the unit body. •Do not connect any load other than a three-phase inductive motor to the U, V, and W output terminals. •Take sufficient shielding measures when using the product in the following locations.
Not doing so may result in damage to the product. Locations subject to static electricity or other forms of noise. Locations subject to strong magnetic fields. Locations close to power lines. 2 Design Precautions for Use „ Installation •Install the Inverter vertically on the wall or DIN tracks (optional). Install the Inverter on a nonflammable wall surface material, like metal. Positions for installing screws Position for installing a screw Model 3G3JX-A2002 A2004 A2007 AE002 AE004 Model 3G3JX-A2015 A2022 A2037 A4004 A4007 A4015 A4022 A4037 AE007 AE015 AE022 Screw size for installation: M5 Screw size for installation:
M5 Position for installing a screw Positions for installing screws Position for installing a screw Model 3G3JX-A2055 -A2075 -A4055 -A4075 Screw size for installation: M6 Position for installing a screw 2-2