Chapter 1 Product Overview Error Status There are two possible error types: recoverable errors and unrecoverable errors. Recoverable Errors Processing is no longer possible when recoverable errors occur. They can be recovered easily by turning the power off and then on again or sending an error recovery command from the driver after eliminating the cause of the error. 1 27 Error Error description Error LED flash code Approx.320 ms Approx.5120ms Recovery measure Mechanism position error When any of the following errors occurs during the initialization and operation. • Error detected during hopper position detection operation. • Error detected during franker position detection operation.
• Error detected during pocket switch board position detection operation. Remove the cause (foreign matter or papers) and call BiCancelError of the TM-S1000 API or turn off/on the power.