EN | 008 Charging Mode Parameters Description SUPPLY 11~16.8V 5~120A In this mode, the output voltage is constant, and the output current is up to the load to be charged (but won’t exceed the maximum current set by the user). The maximum output power is 1700W. This mode is suitable for two scenarios: & . (The battery clamp voltage is greater than 3V or close to 0V.) During charging, the charging voltage and current can be modified. Press on T120A. Then press or to choose or . After that, press . Then press or to modify the voltage. After that, press . Then press or to modify the current. After that, press .
(Charging will be based on the new voltage and current.) Lead Acid NORM 14.2V This mode follows a stepwise charging algorithm that delivers constant voltage or current at different steps. It can be used to charge 12V lead-acid batteries, including WET, GEL, MF, CAL, EFB, and AGM.