Delta Electronics — 3.1.3 Load Cell Full Screen Display

TP70P-211LC1T/TP04P-20EXL1T Operation Manual (3) Unstable When the weight value is not stable, the Unstable in the bulletin is highlighted in a red block. When the weight value is stable, the Motion in the bulletin is highlighted in a green block. (4) Cal. Issue When an error occurs, for example, putting a higher value for a lighter weight, even if the calibration is done, the Cal. Issue in the bulletin is highlighted in a red block. When this warning appears, the weight value is not reliable. _3 (5) Overflow After calculation, the load weight on the weighing platform converts to a digital value.

If the digital value exceeds the maximum allowable number, the Overflow in the bulletin is highlighted in a red block. (6) Max limit, the Max in the bulletin is highlighted in a red block. You can set up a weight maximum limit in the Load Cell Setup page. When the weight used exceeds the maximum (7) Power When the power supply is abnormal, the Power in the bulletin is highlighted in a red block. (8) Zero Reset Reset the present value to zero. (9) Unit Setup Here you can select the weight unit, in kilogram or in gram. 3-8