PLC-API tTaskCycleTime : Cycle time with which the function block is called. If the function block is called in every cycle this corresponds to the task cycle time of the calling task. nSamplesToFilter : The number of values, n, whose arithmetic average value is calculated. pWorkArray_ADR : The address of the array where the input values are temporarily stored. nWorkArray_SIZEOF : Size of the WorkArray. Requirements 5.5.5 FB_CTRL_LEAD_LAG The function block represents a digital lead/lag filter. Transfer function: TS4100 84 Version:
1.1 Development Environment Target System PLC libraries to include TwinCAT v2.8 PC (i386) TcControllerToolbox.lib TwinCAT v2.9 from Build 947 BC [} 10] TcControllerToolbox.lb6 TwinCAT v2.9 from Build 956 BX [} 10] TcControllerToolbox.lbx