TcXaeMgmt Version 7.X | Get-TcDataType -NoReset By default, the Maximum Delay of the PerformanceData before getting new data is reset. Switching to -NoReset remains the maximum Delay between calls. Resets MaxDelay if true. Type: SwitchParameter Parameter Sets: (All) Aliases: Required: False Position: Named Default value: False Accept pipeline input: False Accept wildcard characters: False CommonParameters This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters .
INPUTS TwinCAT.IRoute TwinCAT.ISession OUTPUTS NOTES 6.35 Get-TcDataType | Get-TcDataType SYNOPSIS Get the DataTypes from a TwinCAT target system / Device. SYNTAX NetIdPort (Default) Get-TcDataType [[-Name] ] [-NetId ] -Port [-ResetSymbols] [-Force] [- AsJson] [ ] Route Get-TcDataType [[-Name] ] -Route -Port [-ResetSymbols] [-Force] [-AsJson] [ ] AddressStr Get-TcDataType [[-Name] ] -Address -Port [-ResetSymbols] [-Force] [- AsJson] [ ] Session Get-TcDataType [[-Name] ] -Session [-ResetSymbols] [-Force] [-AsJson] [ ] TE1000 148 Version: 1.5.0