TcXaeMgmt Version 7.X | Get-TcDataType Type: ISession Parameter Sets: Session Aliases: InputObject Required: True Position: Named Default value: None Accept pipeline input: True (ByValue) Accept wildcard characters: False -SessionId The unique session Identifier that represents the session to ose for the datatype upload. Tab completion: Completes IDs of active TwinCAT sessions (created with New-TcSession). The port. Type: Int32 Parameter Sets: SessionId Aliases: Id Required: True Position: Named Default value: -1 Accept pipeline input: False Accept wildcard characters: False -ResetSymbols Resets the symbols and datatypes cache. Reset Symbols/Datatypes flags Type:
SwitchParameter Parameter Sets: (All) Aliases: Required: False Position: Named Default value: False Accept pipeline input: False Accept wildcard characters: False -Force Forces the ADS access. The force switch Type: SwitchParameter Parameter Sets: (All) Aliases: Required: False Position: Named Default value: False Accept pipeline input: False Accept wildcard characters: False -AsJson Exports the data as Json. The asJson switch Type: SwitchParameter Parameter Sets: (All) Aliases: Required: False Position: Named Default value: False Accept pipeline input: False Accept wildcard characters: False TE1000 151 Version: 1.5.0