beckhoff TE1000 — 6.9 Get-TComObject

TcXaeMgmt Version 7.X | Get-TComObject PARAMETERS -Name Optional TCOM object name filter(s). Wildcards are permitted. Type: String[] Parameter Sets: (All) Aliases: Required: False Position: 0 Default value: None Accept pipeline input: False Accept wildcard characters: True -ClassId Optional TCOM class identifier filter(s). Wildcards are permitted. Type: String[] Parameter Sets: (All) Aliases: Required: False Position: Named Default value: None Accept pipeline input: False Accept wildcard characters: True -NetId The address where to get TCOM Objects. Tab completion: Completes AmsNetId values from currently reachable routes on the local TwinCAT system. The NetId.

Null is not a valid value for the NetId parameter! Type: AmsNetId Parameter Sets: NetIdPort Aliases: Required: False Position: Named Default value: None Accept pipeline input: False Accept wildcard characters: False -Address The address(es) where to get the TCOM Objects. This can be the RouteName, NetId, the HostName or the IPAddress. Wildcards are permitted. Tab completion: Completes route names from currently reachable ADS systems on the local TwinCAT system. The address. Type: String Parameter Sets: AddressStr Aliases: Required: True Position: 1 Default value: None Accept pipeline input: False Accept wildcard characters:

True -Session The Session to use for the Cmdlet, must be connected to port 10, R0_TComServer The Session. Type: ISession Parameter Sets: Session Aliases: InputObject Required: True Position: Named TE1000 67 Version: 1.5.0