sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 118 asynchronous motor on the motor type F14.10 Rotor resistance of asynchronous motor 1~60000 (rated power of motor: ≤75 kW) 0.1~6000.0 (rated power of motor: > 75kW) mΩ Depen ding on the motor type 〇 0x0E0A F14.11 Leakage inductance of asynchronous motor 0.01 to 600.00 (rated power of motor: ≤75 kW) 0.001 to 60.000 (rated power of motor: > 75 kW) mH Depen ding on the motor type 〇 0x0E0B F14.12 Mutual inductance of asynchronous motor 0.1 to 6000.0 (rated power of motor: ≤75 kW) 0.01 to 600.00 (rated power of motor:

> 75 kW) mH Depen ding on the motor type 〇 0x0E0C F14.13 No-load excitation current of asynchronous motor 0.01 to 600.00 (rated power of motor: ≤75 kW) 0.1 to 6000.0 (rated power of motor: > 75 kW) A Depen ding on the motor type 〇 0x0E0D F14.14 Flux weakening coefficient 1 of asynchronous motor 10.00 ~ 100.00 % 87.00 〇 0x0E0E F14.15 Flux weakening coefficient 2 of asynchronous motor 10.00 ~ 100.00 % 80.00 〇 0x0E0F F14.16 Flux weakening coefficient 3 of asynchronous motor 10.00 ~ 100.00 % 75.00 〇 0x0E10 F14.17 Flux weakening coefficient 4 of asynchronous motor 10.00 ~ 100.00 % 72.00 〇 0x0E11