User Manual of EM730 Series Inverter 129 6:extruder application 7:high-speed motor application 8:plastic extruding machine 9:EM100 comm macro 10: EM303B comm macro F16.01 Set length 1 ~ 65535 (F16.13=0) 0.1 ~ 6553.5 (F16.13=1) 0.01~ 655.35 (F16.13=2) 0.001 ~ 65.535 (F16.13=3) m 1000 ● 0x1001 F16.02 Pulses per meter 0.1 ~ 6553.5 100.0 ● 0x1002 F16.03 Set count value F16.04 ~ 65535 1000 ● 0x1003 F16.04 Specified count value 1 ~ F16.03 1000 ● 0x1004 F16.05 Set time of regular running 0.0~ 6500.0, 0.0 is invalid min 0.0 ● 0x1005 F16.06 Agent password 0~65535 0 ● 0x1006 F16.07 Setting of cumulative power-on arrival time 0-65535; 0:
disable the protection when the power-on time is up h 0 ● 0x1007 F16.08 Setting of cumulative running arrival time 0-65535; 0: disable the protection when the running time is up h 0 ● 0x1008 F16.09 Factory password 0~65535 XXX X ● 0x1009 F16.10 Analog output percentage corresponding to the count value 0 0.00 ~100.00 % 0.00 〇 0x100A F16.11 Analog output percentage corresponding to the set count value 0.00 ~100.00 % 100.0 0 〇 0x100B