User Manual of EM730 Series Inverter 138 F19.12 Category of two previous protections same as F19.00 parameter description 0 × 0x130C F19.13 Output frequency in protection Hz 0.00 × 0x130D F19.14 Output current in protection A 0.00 × 0x130E F19.15 Bus voltage in protection V 0 × 0x130F F19.16 Operating status in protection same as F19.04 parameter description 0 × 0x1310 F19.17 Working time in protection h 0 × 0x1311 F27 Winding/unwinding application macro parameter group F27.00 Application macro 0: winding mode 1: unwinding mode 2: wire drawing mode 3: straight wire drawing machine mode 0 〇 0x1B00 F27.01 Feedforward gain action channel 0: feedforward gain * set source B 1:
feedforward gain * set source A 2: feedforward gain * 10V 1 〇 0x1B01 F27.02 Feedforward gain input mode 0: no change in feedforward gain 1: 0.00 to upper limit of feedforward gain 2: - upper limit of feedforward gain to + upper limit of feedforward gain 1 〇 0x1B02 F27.03 Feedforward control Ones place: feedforward reset option 0: automatic reset 1: terminal reset Tens place: feedforward power-off stop option 0: save after power failure 1: not save after power failure Hundreds place: options of continuous feedforward calculation 0: not calculate 1: calculate 10 〇 0x1B03 F27.04 Upper limit of feedforward gain 0.00~500.00 % 500.0 0 〇 0x1B04