User Manual of EM730 Series Inverter 140 0: protection of terminal action only 1: delayed stop and trip protection 2: material cutoff protection 3: automatic reset after protection shutdown 4: material cutoff detection terminal output only (straight wire drawing machine) 5: automatic reset of cutoff detection terminal (straight wire drawing machine) Thousands place: brake mode 0: mode 0 1: mode 1 Myriabit: reverse unwinding mode 0: no speed limit 1:
reverse speed limit by F27.24 F27.21 Material cutoff detection delay 0.0~10.0 S 6.0 ● 0x1B15 F27.22 Lower limit of material cutoff detection after parking 0.00 ~ 60.00 Hz 5.00 ● 0x1B16 F27.23 Time of continuous running after material cutoff 0.0 ~ 60.0 S 10.0 ● 0x1B17 F27.24 Frequency of continuous running after material cutoff 0.00~Fmax Hz 5.00 ● 0x1B18 F27.25 Brake signal output frequency 0.00~FUP Hz 2.50 ● 0x1B19 F27.26 Braking signal duration 0.0~100.0 S 5.0 ● 0x1B1A F27.27 Minimum frequency of wiring detection 0.00~20.00 Hz 10.00 ● 0x1B1B F27.28 Judgment time for invalid cable signal 0.1 ~ 20.0 S 10.0 ● 0x1B1C F27.29 Judgment time for valid cable 0.1 ~ 20.0 S 2.0 ● 0x1B1D