User Manual of EM730 Series Inverter The function codes F01.19 to F01.23 are the parameters of the synchronous motor. They are usually unavailable to users. Please get them through motor parameter self-identification (F01.34). according to the actual situation. In particular, select the motor type (F01.00=2) correctly. Before the motor parameter self-identification, be sure to set F01.00 to F01.08 correctly F01.34=0 : not identified F01.34=1 : the asynchronous motor remains stationary during parameter self-identification. Prior to the static self-learning of the asynchronous motor, please set the motor type (F01.00) and motor nameplate parameters (F01.01 to F01.08) correctly.
Relevant parameters (F01.09 to F01.13) of the asynchronous motor can be obtained during static self-learning. 170 F01.20 d-axis inductance of synchronous motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.001 to 60.000 (rated power of motor: > 75 kW) mH Model Confirm 〇 0x0114 F01.21 q-axis inductance of synchronous motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.001 to 60.000 (rated power of motor:
> 75 kW) mH Model Confirm 〇 0x0115 F01.22 Counter electromotive force of synchronous motor 10.0~2000.0 (counter electromotive force of rated speed) V Model Confirm 〇 0x0116 F01.23 Initial electrical angle of synchronous motor 0.0~359.9 (valid for synchronous motor) 0.0 〇 0x0117 Function code Function code name Parameter description Unit Default setting Attribute mailing address F01.34 Motor parameter self-learning 0: no operation 1: static self-learning of asynchronous motor 2: rotation self-learning of asynchronous motor 11: static self-learning of synchronous motor 12: rotary self-learning of synchronous motor 0 〇 0x0118