sinee — 7.3Function Parameter Group of Input Terminal of F02

User Manual of EM730 Series Inverter terminals (X1 to X5) and two analog input terminals (AI1 and AI2, to be used with the corresponding function set to digital input, as detailed in the F02.31 description). The terminals X1 to X5, AI1 and AI2 are seven multi-function input terminals. The functions of the input terminals can be defined by setting the values of the function codes F02.00 to F02.14. For example, if you define F02.00=1, the function of the X1 terminal is “RUN”. If the command source is set to terminal control (F00.02=1) and the X1 terminal input is valid, the “RUN” function of the inverter will be enabled. Specific options are described in Table 7-6.

function status is dependent on the “OR logic” of the two terminals. In the case of F02.00=1 and If multiple terminals are set to the same function (except for #34 function terminal), the F02.04=1, once one of the terminals X1 or X5 is valid, the “RUN” function of the inverter will be enabled.

Table 7- 6 Function List of Multi-function Digital Input Terminals 172 Function code Function code name Parameter description Unit Default setting Attribute mailing address F02.00 Options of X1 digital input function See Table 7-6 Function List of Multi-function Digital Input Terminals 1 〇 0x0200 F02.01 Options of X2 digital input function 2 〇 0x0201 F02.02 Options of X3 digital input function 11 〇 0x0202 F02.03 Options of X4 digital input function 12 〇 0x0203 F02.04 Options of X5 digital input function 13 〇 0x0204 F02.07 Options of AI1 digital input function 0 〇 0x0207 F02.08 Options of AI2 digital input function 0 〇 0x0208 Settings Function Description 0 No function Disable the protection terminal or set it to “0:

Unavailable” to prevent malfunction. 1 Running terminal (RUN) When the command source is set to terminal control (F00.02=1), and the function terminal is valid, the inverter will execute the corresponding RUN function according to the set value of the terminal control mode option (F00.03). (See the explanation of the function code F00.03 for details.) 2 Running direction When the command source is set to terminal control