User Manual of EM730 Series Inverter When the bit is set to 0, the multi-function input terminal is valid in the closed status and Fig. 7- 12 Schematic Diagram of Positive/Negative Logic Sampling of Terminal 179 cutoff signal used for external input of material cutoff detection. When material cutoff detection is an external signal and the terminal is closed (consistent with restrictions), E43 protection will be reported. 122 Wiring detection signal This is a dedicated function for winding applications, which is used for wiring detection. When the valid or invalid time of the wiring detection signal expires, E44 protection will be reported.
123 Brake reset terminal This is a dedicated function for winding applications. When the brake output is valid, this terminal can be closed to reset the brake output. Function code Function code name Parameter description Unit Default setting Attribute mailing address F02.15 Positive/ negative logic 1 of digital input terminal D7 D6 D5 D4 D3 D2 D1 D0 00000 〇 0x020F * * * X5 X4 X3 X2 X1 0: positive logic is valid in the closed state/invalid in the open state 1: negative logic is valid in the closed state/invalid in the open state F02.16 Positive/ negative logic 2 of digital input terminal D7 D6 D5 D4 D3 D2 D1 D0 00 〇 0x0210 * * * * * * AI2 AI1 0:
positive logic is valid in the closed state/invalid in the open state 1: negative logic is valid in the closed state/invalid in the open state