User Manual of EM730 Series Inverter Fig. 7-16 Acceleration/Deceleration Time Control Diagram F04.19=0: deceleration to stop The motor decelerates to stop according to the set deceleration time [default setting: based on F00.15 (deceleration time 1)]. F04.19=1: free stop When the stop command is valid, the inverter will stop output immediately, and the motor will freely coast to stop. The stop time depends on the inertia of the motor and load. If the free stop terminal has been set and enabled, the inverter will be immediately in the free stop status. Even if this terminal is disabled, the inverter will not restart running.
Instead, the running command must be entered again to start the inverter. 202 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F04.19 Stop mode 0: slow down to stop 1: free stop 0 〇 0x0413