User Manual of EM730 Series Inverter The torque depends on the communication and the like. If the master-slave communication (F10.05=1) is enabled and the inverter works as the slave (F10.06=0), the specific feedback percentage is “700FH (master-slave communication setting) * F10.08 (slave receiving proportional coefficient)”, and the 700FH data range is -100.00% to 100.00%, as detailed in Table 12-31. (torque communication setting) * F13.02 (digital torque setting)”, and the 7003H data range For the general communication (F10.05=0), the specific setting percentage is “7003H is -200.00% to 200.00%, as detailed in Table 12-31. F13.01=8:
digital potentiometer setting In the torque mode, the torque is directly set by the digital potentiometer. See F12.43 for the specific value. torque function. Specifically, the input terminal functions “17: multi-segment torque terminal 1” For diversified torque applications, the EM730 series inverter supports the multi-segment and “18: multi-segment torque terminal 2” need to be set. See the instruction Table 7-21 for details.
Table 7- 21 Combination of Multi-segment Torque Command and Multi-segment Torque Terminal 267 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F13.03 Multi-segment torque 1 -200.0 ~ 200.0 % 0.0 ● 0x0D03 F13.04 Multi-segment torque 2 -200.0 ~ 200.0 % 0.0 ● 0x0D04 F13.05 Multi-segment torque 3 -200.0 ~ 200.0 % 0.0 ● 0x0D05 18: multi-segment torque terminal 2 17:
multi-segment torque terminal 1 Number of Segments Torque setting Invalid Invalid Multi-segment torque 1 Depending on the F13.01 setting Invalid Valid Multi-segment torque 2 F13.03 Valid Invalid Multi-segment torque 3 F13.04 Valid Valid Multi-segment torque 4 F13.05 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F13.06 torque control acceleration and deceleration time 0.00 ~ 120.00 s 0.05 ● 0x0D06